News Release from: Christison Particle Technologies | Subject: Flow microscopy
Edited by the Manufacturingtalk Editorial Team on 15 June 2007

Analysis of parenteral particle
formulations

Request your FREE weekly copy of the Manufacturingtalk email newsletter. News about Materials Testing and more every issue. Click here for details.

Flow microscopy introduced by Christison Particle Technologies enables efficient, discriminating, characterisation of parenteral particle populations.

Particles in parenteral formulations can be efficiently counted and measured at speed with Christison Particle Technologies' flow microscopy The Micro Flow technology allows the analysis of formulation components, contaminants and manufacturing artifacts, enabling a more consistent and safe gauge of product acceptability

Particle detection and measurement in parenterals has been extensively investigated.

USP General Chapter 788 specifies light obscuration and microscopy as the methods for counting and sizing particles.

However, both techniques have limitations: Light blockage under-sizes and under-counts non-spherical and translucent particles.

Microscopy is time-consuming, tedious and operator-dependent.

Image Analysis has been previously investigated as a means to improve the efficiency of the manual microscopic method.

Doubts have been raised as to the ability of Image Analysis systems to capture the smallest product particles, and to provide a comprehensive analysis of a sample Flow Microscopy, the technique utilised by Brightwell Technologies MFI TM delivers the instrumental benefits (consistency, reliability, speed) of light blockage methods alongside the precision, sensitivity and additional information (size, shape, image) of manual microscopy.

Protein formulations present a significant challenge to particle detection and measurement.

Particles formed by protein aggregation are Translucent, Irregular sizes and shapes, Fragile and easily deformed, Present in very low concentrations.

Particles with these characteristics cannot be reliably detected and measured by light obscuration In the Brightwell Technologies system the sample is drawn through a precision Flow Cell.

A range of delivery options ensures that the sample is delivered with the least possible damage to fragile particles.

Images are acquired many times each second.

All particles in frame are detected and measured.

Results are presented as concentration vs size histograms.

Multidimensional size data is recorded which allows morphological analysis of particles.

Real time data processing enables continuous sampling and trend charting, while particle images can be simultaneously viewed to allow confirmation of the nature of particles.

Dave Thomas of Brightwell Technologies reports, "Flow Microscopy typically detects ten times as many particles in a Parenteral Solution compared to a light obscuration technique.

The technology is highly effective in addressing the challenges encountered upon measuring very low concentrations of broadly heterogeneous particles.

When you consider that in addition we can individually view each particle and segregate particle populations based on a multitude of morphological parameters, you see the benefit of the system".