News Release from: Copley Scientific | Subject: Dry powder inhaler tester
Edited by the Manufacturingtalk Editorial
Team on 02 April 2007
Dry powder inhaler testing and document
control
Designed to control and document critical parameters with dose uniformity and cascade impactor testing for dry powder inhalers is the the Critical Flow Controller TPK 2000 from Copley Scientific.
The Critical Flow Controller TPK 2000 from Copley Scientific is designed to control and document all the critical parameters associated with dose uniformity and cascade impactor testing for dry powder inhalers (DPIs) Based on the company's original TPK critical flow controller, now widely recognised as an industry standard, it offers significant ly enhanced functionality including an RS232 interface, menu driven operation and environmental condition measurement
This article was originally published on Manufacturingtalk on 1 Mar 2007 at 8.00am (UK)
Related stories
Spray force tester for medical devices
Copley Scientific has launched the Copley Spray Force Tester SFT 1000 measures impaction force as a parameter for spray characterisation.
Quality solutions for inhaler testing brochure
Copley Scientific, a leading supplier of inhaler test equipment, has released an inhaler testing brochure entitled, 'Quality solutions for inhaler testing - 2007 Edition'.
The US and European Pharmacopoeias (USP and Ph.
Eur) specify that flow rate, total air volume and flow stability must be carefully controlled during DPI testing.
Flow rate must be manipulated to generate a 4 kPa pressure drop across the DPI, up to a maximum flow of 100 L/min, with the duration of flow controlled to give a total air volume of 2 or 4 L.
Critical flow across the flow control valve is also required to minimise flow rate instability.
The TPK 2000 makes test set-up easy in line with these specifications.
A user-friendly interface provides guidance through the testing procedures specified by the pharmacopoeias.
Following an initial set-up procedure, which identifies the air flow rate required for testing based on the flow resistance of the device, the TPK 2000 automatically measures and/or calculates all required variables including,test flow rate and ambient conditions - air pressure, temperature and relative humidity - as well as monitoring critical flow.
These parameters along with system calibration data can be printed or exported via RS232 (or USB).
An optional interface with Copley's flow meter model DFM 2000 permits volumetric air flow rate measurement during the set-up routine, simplifying and accelerating this part of the procedure.
utilising two external pressure taps the TPK 2000 can also be used to determine leak rates and total pressure drops for both Next Generation and Andersen Cascade Impactors; valuable data for monitoring day-to-day impactor performance and suitability.
The TPK 2000 is designed for user calibration within the lab environment.