News Release from: Gardner Energy Management | Subject: Efficient steam trap
Edited by the Manufacturingtalk Editorial
Team on 29 December 2006
Efficient steam trap top in trials
A performance analysis has shown that, over varying condensate loads and steam pressures, the GEM venturi trap, manufactured by Gardner Energy Management, is the most efficient steam trap available.
A performance analysis carried out by Queen's University, Belfast into efficiency of steam traps has shown that, over varying condensate loads and steam pressures, the GEM venturi trap, manufactured by Gardner Energy Management, is the most efficient steam trap available The testing was undertaken under the supervision of Dr Gavin Walker BSc, MSc, PhD, Senior Lecturer in Chemical Engineering at Queen's University, Belfast and carried out under BS EN 27841: 1991
This article was originally published on Manufacturingtalk on 21 Nov 2006 at 8.00am (UK)
Related stories
Steam trap offers up to 55% energy saving
Instead of using a valve mechanism to close off steam a steam trap uses a patented venturi orifice to drain condensate from the steam system and realise energy savings up to 55%.
Energy management to prevent waste
The Carbon Trust asserts that UK companies waste GBP1bn a year on energy largely due to energy plant optimisation issues, energy wastage and inefficient energy usage across the manufacturing site.
It was decided that a variety of steam traps would be utilised in the research including buckets, floats, thermostatic and thermodynamic valve arrangements.
Only new traps were used even though it had been previously noted that the performance of mechanical and thermostatic traps diminishes over time as components wear and progressively fail.
A glass constructed 'climbing film evaporator' test rig was used as it enabled the flow of steam and condensate to be monitored visually.
Further reading
Steam traps save in energy costs
Aesica is saving over GBP67,000 a year in energy costs at its Ponders End site following the installation of steam traps from Gardner Energy Management.
Steam traps for screwed pipework applications
The GEM Sapphire has been specifically developed for screwed pipework applications, the Gardner Energy Management steam traps helping to save energy.
Venturi steam traps minimise steam loss
Venturi orifice steam traps, fitted to feedwater heat exchangers, air heater batteries and distribution lines, are minimising steam loss at a UK food manufacturing plant.
The rig was designed to work like a normal heat exchanger but had the advantage of enabling heat outputs, and therefore condensate loads, to be altered by regulating the flow of evaporative liquid on the secondary side of the exchanger.
This changed the liquid level, and therefore the heat transfer area of the exchanger, without changing steam pressure.
It was decided that the performance analysis would be carried out under maximum steam pressure, utilising a full range of condensate flows, to fully test the traps.
However, most industrial variable load applications are fitted with control valves so as the heat loads vary, the steam pressure will be regulated.
Therefore at low loads there is less condensate produced and less steam pressure exerted on the trap.
Tests were performed on each trap at a constant pressure of 54 psig (3.7bar) and varying flows from 'no flow' to 20 kg/hr.
'Bucket tests' were conducted according to the European Standard to measure the live steam loss through traps at five various condensate load conditions expressed as the level of liquid in the evaporative column in the rig.
The results proved that the GEM venturi steam trap is significantly more efficient over varying loads than all other types of traps with the free floating float trap and the more conventional float trap the least efficient with losses averaging over 1.5 kg/hr.
The TD thermodynamic and 'MK' thermostatic traps were slighting more efficient but all traps were less efficient than the GEM trap.
The BPT balanced pressure thermostatic traps were significantly more efficient than any other types of trap at high condensate loads but the GEM was found to be significantly more efficient over varying loads.
In addition the tests also proved, unequivocally, that the GEM trap is more efficient than mechanical traps, disproving previous perceptions that orifice venture traps are inefficient at low load conditions when there is little condensate present to hold back the steam.
Commenting Tim Gardner, Managing Director of Gardner Energy Management said: "This research, carried out under the most stringent conditions, has underlined the superiority of the GEM trap.
In addition as GEM traps have no moving parts to fail or wear out it obviates the need for continual trap testing, repair and replacement".
• Gardner Energy Management: contact details and other news
• Email this article to a colleague
• Register for the free Manufacturingtalk email newsletter