Product category:
Monitoring and sensor equipment and systems
News Release from: Hydramotion | Subject: Intrinsically safe in-line viscometers
Edited by the Manufacturingtalk Editorial
Team on 25 April 2006
In-line viscometer keeps the lacquer
flowing
Intrinsically safe in-line viscometers are playing a critical role in the production of polymer-coated cellulose films used worldwide in speciality packaging and labelling.
Intrinsically safe in-line viscometers are playing a critical role in the production of polymer-coated cellulose films used worldwide in speciality packaging and labelling Intrinsically safe in-line viscometers from Hydramotion are playing a critical role in the production of polymer-coated cellulose films by a major UK manufacturer
This article was originally published on Manufacturingtalk on 16 Jul 2004 at 8.00am (UK)
Related stories
Portable viscosity measurement made on site
Portable process viscometer can be used with any volume of fluid to give instant spot measurement of viscosity in the field, factory or lab without requiring any on-site set-up or calibration.
Viscosity measurement website expanded
Hydramotion has added sixteen new pages to its website, offering visitors valuable information, free downloads and an interactive viscosity units conversion table.
Cellulose films are used worldwide in speciality packaging, labelling, graphic arts and security products.
During the manufacturing process, the film is coated with a solvent-based lacquer which controls the barrier properties of the finished product (e g, permeability to aromas, gases or moisture).
Maintaining the correct viscosity of the lacquer is vital for ensuring a constant and controllable coating laydown by the gravure coater.
In this case, a Hydramotion XL7 viscometer is mounted in a 90 deg bend at the entry to the lacquer storage tank on each line in the production facility.
As lacquer circulates between the tank and the applicator, the temperature-corrected viscosity signal from the XL7 is used by the process PLC to modulate the addition of virgin solvent, maintaining lacquer viscosity at the correct level and minimising costly downtime.
Hydramotion was initially selected because it could supply Intrinsically Safe viscometers certified for Zone 0 (Class 1 Div 1 Group A) Hazardous Area operation.
In addition, the XL7 in-line viscometer has no moving parts, simplifying maintenance.
As one of the engineering managers at the site commented, "The construction is robust and easy to install and maintain." The Hydramotion viscometers were first installed ten years ago, when the customer opened a new lacquer production facility with the aim of streamlining production and reducing the number of shifts from three to two, with consequent savings in labour costs.
At that time, the customer was relying for viscosity measurement on a crude timed falling plunger system, which was described as: "Vastly inferior in terms of accuracy, reliability and operability." The old system had no temperature compensation, calibration was regularly affected by mechanical wear, and the equipment required frequent cleaning and maintenance. Request a free brochure from Hydramotion ...
• Hydramotion: contact details and other news
• Email this article to a colleague
• Register for the free Manufacturingtalk email newsletter
• Manufacturingtalk Home Page