Product category:
Measurement and Quality Software and SPC
News Release from: Lambda Advanced Technology | Subject: Flame atomic absorption spectrophotometery
Edited by the Manufacturingtalk Editorial
Team on 21 March 2006
Flame atomic absorption
spectrophotometery
A completely new approach to flame atomic absorption spectrophotometery (AAS) has been launched in the UK by Lambda Advanced Technology.
A completely new approach to flame atomic absorption spectrophotometery (AAS) has been launched in the UK by Lambda Advanced Technology The contrAA 300 from Analytik Jena AG combines the simplicity of AAS with the speed and flexibility of ICP spectrometry by utilising a high resolution continuum light source in conjunction with a high resolution double Echelle monochromator for the first time in the technique
This article was originally published on Manufacturingtalk on 18 Mar 2003 at 8.00am (UK)
Related stories
Prodigious Performance From L-PAD ICP Spectrometer
The new Prodigy high dispersion simultaneous ICP (inductively coupled plasma) optical emission spectrometer from Leeman Labs is now available in the UK from Lambda Advanced Technology.
21 CFR 11 UV And FL Solutions Software Announced
Lambda Advanced Technology is delighted to announce the availability of 21 CFR Part 11 versions of the respected UV Solutions and FL Solutions control software.
This increases sample throughput, improves detection limits and reduces costs.
This novel approach means that all atomic absorption lines from 190 - 900 nm are available from a single light source without the necessity for a different hollow cathode lamp for each element of interest.
Each sample can be analysed sequentially for each element instead of having to measure one element on each sample, change lamps, then measure the next element on each sample and so on.
The high intensity light source and back-thinned CCD detector bring enhanced sensitivity and improved detection limits.
For example, 0.1 parts per million Pb can be detected in 1 g/L Fe solution.
The system also provides simultaneous real time registration of both analyte and background, using a pixel referencing technique instead of complex and expensive D2 or Zeeman background correction methods.
This technique corrects for lamp drift, variations in thermal emission and unspecified background absorptions, leading to faster and more accurate measurements.
To cover the full range of elements accessible by flame AAS, 67 different lamps would be required.
Not only is this an expensive option, especially for rarely analysed elements, but most instruments will hold a maximum of just 8 lamps on an adjustable turret.
All lines are available on the contrAA 300 from a single, high intensity xenon short-arc lamp. Request a free brochure from Lambda Advanced Technology ...
• Lambda Advanced Technology: contact details and other news
• Email this article to a colleague
• Register for the free Manufacturingtalk email newsletter
• Manufacturingtalk Home Page

