Categories
- Machine Tools: Cutting (3,917)
- Machine Tools: Metalforming, shearing, folding and punching (1,481)
- Machine Tools: moulding (1,058)
- Cutting tools (1,766)
- Welding and Joining (1,488)
- Finishing, preparation, coating and painting (1,025)
- Automation and assembly systems (1,044)
- Manufacturing support (8,593)
- Industry news, commerce, exhibitions, education (8,185)
- Packaging (2,865)
- Specialist Manufacturing Sectors and Metals Producing (1,318)
- Books, CDs and Videos (189)
- IT for manufacturing management and production (3,425)
- IT for engineering, industrial and commercial applications (4,837)
- Manufacturing IT hardware and communications (1,569)
- Used machinery and machine tools (29)
- Materials handling and storage (912)
- Wood and non-metallics working (73)
- Metrology instruments and systems (3,798)
- Testing and quality control systems and services (4,939)
- Subcontracting services (1,142)
Compact panel-mounted current transducer
LEM has introduced the LA 306-S, a panel-mounted current transducer for the measurement of currents up to 400 ARMS and only 56mm high.
LEM has introduced the LA 306-S, a panel-mounted current transducer for the measurement of currents up to 400 ARMS (@ +70degC) or 300 ARMS (@ +85degC).
The unit offers the high performance of a closed-loop current transducer at a very competitive price.
The new transducer is only 56mm high.
It features a wide maximum bandwidth of DC to 50kHz and an overall accuracy of better than 0.7 per cent at the primary nominal RMS current.
Typical linearity error is +/-0.1 per cent at nominal current and the maximum offset temperature drift is 500 microamps from -40 to +85degC.
The closed-loop Hall-effect technology results in no insertion losses and a fast response time of less than 1 microsecond.
The transducer's aperture accepts busbars up to 13 x 30mm.
Specified with 2000 turns as standard, it is also available with 5000, 4000 or 3000 turns on request.
A Molex 5045 plug is offered as standard for the secondary connections, to allow quick installation.
A Molex series 70543 connector can be specified for a more robust connection.
With an isolation test voltage of 6kVRMS/50Hz/1min, the transducer complies with the EN50178 industrial standard.
All materials used satisfy UL94-V0.
The LA 306-S is CE marked and is supplied with a five-year warranty, as are all LEM industrial products.
Come and see us at PCIM - Hall 12.402 where you can find out more about these and other LEM products.
We will also be presenting a conference paper on Thursday 24 May at 1400 hrs - A transducer at the limits of current measurement accuracy.