Humidity Calibration System for National
Standards
The validity of measurements made by industrial sensors and instruments is ensured by regular calibration, providing traceability through to a National Standard.
The validity of measurements made by industrial sensors and instruments is ensured by regular calibration, providing traceability through to a National Standard In other words, a field sensor must be calibrated against a reference system that itself has an un-broken chain of calibration through to some primary system, such as operated by National Standards laboratories like NPL in the UK, NIST in the USA and PTB in Germany
This article was originally published on Manufacturingtalk on 15 Apr 2004 at 8.00am (UK)
Related stories
On-Site Relative Humidity Calibration
Opti-Cal offers the opportunity to provide local calibration of RH sensors, without the need to send them away to a traceable laboratory or incur the additional cost of contracted on-site calibration.
Michell moisture control will dew nicely
Michell Instruments has released the SF Series, offering cost-effective control of moisture via dew point measurement.
Alternatively, large independent companies may operate their own primary standards in certain measurement fields such as electrical parameters, pressure etc Therefore there is a need for high quality, reliable and repeatable calibration reference equipment to effect the link between an industrial sensor and the primary standard.
In the field of humidity calibration, Michell Instruments has developed a variety of calibration systems that are suitable for use as a stand-alone facility to provide a high performance level and act as a transfer-standard between a primary humidity standard and the field sensor, or some other reference hygrometer.
Michell has developed an expertise in providing such humidity calibration equipment to cover the full humidity range, from trace moisture measurement at ppm levels through to relative humidity measurement at elevated temperatures.
Further reading
Michell dew point meter has 250m cable
Now having an increased cable length of up to 250m, a dew point meter can be installed remotely to the electronics of the hygrometer, said Michell Instruments.
Trace moisture event sensor introduced
An on-line trace moisture event sensor designed for UHP inert gas applications in semiconductor fabrication provides rapid indication of a moisture event as low as 20 ppb at 1 ppb baseline.
Each system is built to customers' specific requirements.
Normally a calibration system will comprise an integrated compressor/dryer to produce a zero gas ( no moisture) feed into a humidity generator and sensor housing that are designed for the user's specific needs.
The final element of calibration system is always a precision cooled mirror reference hygrometer that provides direct traceability to a primary humidity standard.
A good example is at Justervesenet, the Norwegian standards institute in Oslo.
In the absence of a primary standard within Norway, this institute decided to use two humidity calibration systems supplied by Michell Instruments, one covering the range -90 to +20 oC dew point and the other for the high temperature/high humidity range up to +80 oC dew point.
The S4000 reference hygrometers used in each system are directly calibrated at NPL.
These systems provide Justervesenet the capability to calibrate other reference hygrometers or field humidity sensors with direct traceability to a primary standard, giving the end user added confidence in humidity measurement. Request a free brochure from Michell Instruments ...