How Fresh Are Your Cookies
The 743 Rancimat, from Metrohm allows simultaneous and rapid Oil Stability Indexes (OSI) to be performed.
Modern analytical methods are coming into use on an ever increasing scale in the fields of food production analysis and quality control and for the compliance with international and domestic standards.
Certain analytical procedures whilst being accurate does not always lend themselves to the ever increasing demands of increased production levels i.e they are just not quick enough.
One such technique within the food industry is the ability to predict the shelf life of a fat or oil containing product.
Commercially it would be disastrous for a company to introduce a fat or oil into their product which had only a few weeks before it became rancid by oxidation.
All oils and fats have a resistance to oxidation that depends on the degree of saturation, natural or added antioxidants, prooxidants or prior abuse.
Oxidation is slow until the resistance is overcome at which point oxidation accelerates and becomes very rapid.
The length of time before this rapid acceleration of oxidation is the measure of resistance to oxidation and is commonly referred to as the "induction period".
The official method for determining the "induction period", or Oils Stability (OS) as it is more commonly known, is by determining the Active Oxygen Content (AOCS official method Cd 12-57).
The Active Oxygen Method (AOM) involves the manual taking of samples over a period of time and performing a titration to determine the peroxide number.
This technique whilst being accurate is both labour intensive and takes many days to perform.
A new official method has been introduced for the determination of OS that is both rapid and automated (AOCS official method Cd 12-92, AOCS Cd-12b-92), JOCS 2.4 28.2-93), SLB Section 7.5.4) Metrohm have developed the 743 Rancimat, that allows simultaneous and rapid Oil Stability Indexes (OSI) to be performed.
In the rancimat a stream of purified air is passed through a sample of oil or fat that is held in a heating block.
The effluent air from the sample is then bubbled through a vessel containing deionised water.
The conductivity of the water is continually monitored.
Once the oil starts to oxidise, volatile organic acids, predominantly formic acid, are swept by the effluent stream, through the deionised water, causing a dramatic increase in the conductivity of the water.
The OSI is defined as the point at which there is the maximum change in the rate of oxidation and is evaluated automatically in the Rancimat.
Impressive features of the 743 Rancimat include:- Individual sample temperature settings for each batch of 4 samples Each sample can be started individually One PC can control up to 4 measuring blocks, this means 32 samples can be processed at up to 8 different temperatures.
Wide temperature range 50 to 220Oc Reliable built in air pump with automatic flow control The whole evaluation is automatically controlled by a PC, which runs software based on windows 95/98/NT/ME/2000 or XP.
Automatic evaluation of the results according to set criteria are calculated by the software.
Economic advantages for using the Rancimat * Intelligent warehouse management of oils and fats * Quicker results at reduced costs * Freeing of laboratory staff to do other tasks * Toxic solvents are no longer needed Typical Applications:- * Oxidation stability of oils and fats * Oxidation stability of hazelnuts and almond oils * Oxidation stability of waxes * Oxidation stability of cereals, biscuits and cookies * Oxidation stability of vegetable and motor oils * Oxidation stability of Bio Diesel * Determining the effectiveness of anti oxidants.
Not what you're looking for? Search the site.
Tel +44 1280 824824
-
Oxidative stability of diesel and biodiesel
The 873, based on the 743 Rancimat from Metrohm UK, is specifically designed to analyse the oxidative stability of biodiesel, diesel and blends. -
Determination of the oxidation stability index
Fats are an important component of our diet because they contain essential substances as polyunsaturated fatty acids. -
Evaluating effects of antioxidants on edible oils
Oxidative stability is an important criterion for evaluating the quality of oils, fats and fatty acid methylesters (biodiesel). -
Determination of oxidation stability of Biodiesel
The Metrohm 743 Rancimat is a modern, PC-controlled analytical instrument for the comfortable determination of the oxidation stability of Biodiesel (fatty acid methyl esters, FAME). -
Effectiveness Of Anti Oxidants In Food Materials
Metrohm's new 743 Rancimat uses the technique of thermal oxidations on fats and edible oils.
Categories
- Machine Tools: Cutting (3,996)
- Machine Tools: Metalforming, shearing, folding and punching (1,530)
- Machine Tools: moulding (1,094)
- Cutting tools (1,814)
- Welding and Joining (1,523)
- Finishing, preparation, coating and painting (1,051)
- Automation and assembly systems (1,122)
- Manufacturing support (8,732)
- Industry news, commerce, exhibitions, education (8,285)
- Packaging (2,869)
- Specialist Manufacturing Sectors and Metals Producing (1,339)
- Books, CDs and Videos (202)
- IT for manufacturing management and production (3,165)
- IT for engineering, industrial and commercial applications (4,809)
- Manufacturing IT hardware and communications (1,570)
- Used machinery and machine tools (30)
- Materials handling and storage (960)
- Wood and non-metallics working (74)
- Metrology instruments and systems (3,849)
- Testing and quality control systems and services (5,014)
- Subcontracting services (1,171)