Analysing electroless nickel plating baths
Automated on-line analysis system performs all liquid handling steps such as taking sample aliquots, dosing of reagents, titration and cleaning.
Electroless nickel layers are normally nickel-phosphorus alloys.
For the reductive chemical deposition of nickel with phosphorus inclusions, sodium-hypophosphite is used as the reducing agent (reductant).
To apply even nickel layers to the workpieces, the content of nickel, reductant and the alkalinity have to be determined periodically.
For the determination of the ingredients an automated ProcessLab system can be used.
All liquid handling steps such as taking sample aliquots, dosing of reagents, titration and cleaning are performed by pumps and burets controlled by processLab.
A sample aliquot is transferred either to the vessel for alkalinity and nickel analysis or to the vessel for reductant content determination.
General features of the ProcessLab system include the following.
* Alkalinity, nickel and hypophosphite determination in one system.
* Barcode reader offers automatic method selection by using predefined barcodes.
* Optional liquid level sensors monitor the reagent level and call for manual intervention when required.
* Additional terminals for the I/O controller allow to transmit or receive external signals, for examples a result that is sent to a remote PCS (Process Control System).
An incoming signal can be a density value from a density meter.
This system is very flexible and can be adapted very easily to any specific needs, said Metrohm UK.
If necessary an additional reagent cabinet is available and ProcessLab can be placed on top of it.
There is sufficient space for all reagents, which makes ProcessLab even more practical.
Calibration and storage of the electrodes are as follows.
* The electrodes need no calibration as only inflection point titrations are carried out.
* The electrodes should be stored in demineralised water, for longer times store the pH electrode and Pt Titrode in KCL 3 mol/L and the Cu ISE in a clean and dry place.
Performing the analysis - the sample is filled into a barcode-labelled beaker and put onto the sample processor.
After starting the tiamo method the barcode is scanned and the appropriate analysis tracks are selected (tiamo identifies the predefined barcode string).
With this method no sample table and no manual sample information is used and urgent samples can be inserted at any time.
* Alkalinity determination - titration with HCI - the sample aliquot is filled up with demin.
Water and titrated to the first inflection point with hydrochloric acid standard solution against a combined pH-glass electrode.
As soon as the first inflection point is reached, tiamo calculates the results and, depending on the barcode, either triggers cleaning of the vessel or continues with the nickel determination.
* Nickel determination - titration with EDTA - the addition of a defined amount of buffer pH=10 and titration with EDTA standard solution to one inflection point against a combined Cu-sensitive electrode.
When the titration is finished the vessel is cleaned; the tiamo calculates the result and creates the database entry.
* Hypophosphite determination - -titration with iodine and thiosulfate - a defined amount of iodine solution is added to the sample aliquot and acidified with sulphuric acid.
After the wait time the iodine that has not reacted with the hypophosphite is titrated to one inflection point with thiosulfate standard solution against a Pt Titrode.
When the titration is finished the vessel is cleaned; tiamo calculates the result and creates the database entry.
Literature is as follows.
* Gros, Prof Dr Leo, Bruttel, P, von Kloeden, M (2005) Practical titration, Metrohm Monograph 8.029.5003.
* Haider, Dr C, Electrodes in Potentiometry, Metrohm Monograph 8.015.5003.
Not what you're looking for? Search the site.
Tel +44 1280 824824
-
Metrohm unveils trace metal analyser
Metrohm has released the 797 VA Computrace for trace analysis and metal speciation. -
MISP techniques improve the Professional IC range
Metrohm released the 850 Professional IC and 858 Sample Processor last year, the first IC instruments to contain intelligence as standard within the hardware and software MagIC Net. -
Metrohm offers trade-in for Titrando range
Metrohm's 'Great Titrator Amnesty' is offering a 20 per cent discount off the list price of the Titrando range of titrators on exchange for old titration systems until 12 December 2008. -
Titro Analyzer augments on-line nickel analysers
Applikon Analytical BV's ADI 2016 Titro Analyzer for nickel augments the existing range of on-line analysers available for surface engineering applications. -
Measuring industrial solutions - which electrode?
Metrohm has been asked consistently for a simple review of which electrodes are available for which industrial solution monitoring applications, such as in plating or acid baths, phosphating, etc.
Categories
- Machine Tools: Cutting (3,967)
- Machine Tools: Metalforming, shearing, folding and punching (1,509)
- Machine Tools: moulding (1,077)
- Cutting tools (1,802)
- Welding and Joining (1,506)
- Finishing, preparation, coating and painting (1,039)
- Automation and assembly systems (1,097)
- Manufacturing support (8,664)
- Industry news, commerce, exhibitions, education (8,243)
- Packaging (2,867)
- Specialist Manufacturing Sectors and Metals Producing (1,332)
- Books, CDs and Videos (197)
- IT for manufacturing management and production (3,231)
- IT for engineering, industrial and commercial applications (4,848)
- Manufacturing IT hardware and communications (1,570)
- Used machinery and machine tools (30)
- Materials handling and storage (937)
- Wood and non-metallics working (73)
- Metrology instruments and systems (3,824)
- Testing and quality control systems and services (4,979)
- Subcontracting services (1,165)