Product category:
Adhesives and adhesive bonding equipment
News Release from: Master Bond | Subject: EP21LV (3/5) lexible two component epoxy resin
Edited by the Manufacturingtalk Editorial
Team on 01 February 2005
Reactive resin approved for medical
assemblies
Flexible two component 100% reactive epoxy resin gains full USP Class VI Certification for the assembly of disposable and reusable medical devices and does not contain any solvents.
Master Bond's newly developed flexible two component epoxy resin system EP21LV (3/5) has obtained full USP Class VI Certification for the assembly of disposable and reusable medical devices This unique flexible epoxy resin compound is 100% reactive and does not contain any solvents or other volatile ingredients
This article was originally published on Manufacturingtalk on 18 Jun 2008 at 8.00am (UK)
Related stories
Adhesive cures very quickly at room temperature
Master Bond has developed an exceptionally fast curing two component epoxy adhesive for general purpose bonding and develops high bond strength exceeding 140kg/cm2 at room temperature.
Epoxy 'Super Glue' offers 3 minute set
A two component epoxy adhesive sets in 3 min for high performance general purpose bonding and cures in a few hours at ambient temperatures to develop a high bonding shear strength.
It cures readily at ambient or more quickly at moderately elevated temperatures.
The cured flexible polymer compound exhibits attractive physical strength properties, exceptional toughness and superior resistance to vibration, impact and thermal shock.
Master Bond EP21LV (3/5) polymer system has excellent chemical resistance including exposure to many sterilants and also outstanding electrical insulation characteristics.
The service temperature range extends from as low as -80 deg F to above 250 deg F.
The Master Bond EP21LV (3/5) epoxy compound has many attractive properties for bonding, sealing and casting in the assembly of disposable and reusable medical devices.
It offers excellent bonding characteristics to metals, ceramic, glass, most polymers and elastomers.
The gap filling behavior is most attractive for sealing as well as bonding applications.
Lap shear strength to many different substrates used for the manufacture of medical devices exceeds 1400 lb/in2 with elongations in excess of 25%.
Master Bond EP21LV (3/5) epoxy polymer compound is likewise successfully employed for potting and/or encapsulating disposable and reusable medical devices requiring USP Class VI Certification.
The excellent electrical insulation characteristics, superior impact strength and retention of pertinent performance properties are particularly valuable upon prolonged exposures to adverse environmental conditions.
Additionally the cured EP21LV (3/5) epoxy features remarkably high dimensional stability and durability. Request a free brochure from Master Bond ...
• Master Bond: contact details and other news
• Email this article to a colleague
• Register for the free Manufacturingtalk email newsletter
• Manufacturingtalk Home Page


