Product category:
Manufacturing communication infrastructure
News Release from: Moore Industries International | Subject: TFZ Programmable Fieldbus Temperature Transmitter
Edited by the Manufacturingtalk Editorial
Team on 04 December 2007
Temperature transmitter networks 126
sensors
A programmable fieldbus temperature transmitter saves wire and installation costs by allowing up to 126 devices to be networked onto one, low cost Foundation fieldbus H1 segment.
The TFZ Programmable Foundation Fieldbus Temperature Transmitter can be installed on the same segment with all standard Foundation fieldbus devices, said Moore Industries The TFZ converts a temperature sensor input to a Foundation fieldbus H1, two-way digital communication protocol that is ready for interface to a DCS, computer-based SCADA system, or asset management software
This article was originally published on Manufacturingtalk on 18 Jul 2008 at 8.00am (UK)
Related stories
Temperature sensors avoid furnace shut-downs
There is no need to shut a furnace or boiler down to change the flexible WORM temperature sensors - they can be replaced from outside the boiler or furnace, writes Paul Aloia.
How to cope with fieldbus for the first time
Many automation engineers are meeting fieldbus applications for the first time and Mike O'Neill discusses some issues, and explains how to deal with them.
The TFZ saves wire and installation costs by allowing up to 32 field devices (126 with repeaters) to be networked onto one, low cost Foundation fieldbus H1 segment.
It requires only 10.5mA for normal operation.
The bus-powered, two-wire TFZ offers dozens of input and operation choices.
Further reading
Flexible temperature sensor is a dream to install
Moore Industries International has introduced the Worm flexible sensor which can be installed without removing the transmitter enclosure, thermowell or union components.
Fault tolerant fieldbus brochure
Trunksafe brochure explains why it isn't necessary to duplicate entire segments to achieve redundancy
Trunksafe approved for Fieldbus
Trunksafe power conditioner recognised as fault tolerant fieldbus system
It sets up from the control room over segment wiring, using a standard Foundation fieldbus configuration tool, to handle 14 RTD types, nine thermocouple types, as well as direct millivolt and resistance/potentiometer inputs.
The TFZ is Factory Mutual approved for use in Class I, Division 1, Groups A, B, C, D and Class II and III, Division 1, Groups E, F, G hazardous areas.
It also has NEMA 4X and IP66 ratings, approvals from ATEX, cFMus (US/Canada), IECEx, CSA, cCSAus, CENELEC/ATEX 94/9/EC and ANZEx, and is CE Conformant.
The TFZ operates in ambient temperature ranges of -40 to +85 deg C (-40 to +185 deg F).
* Diagnostics and performance - TFZ transmitters perform continuous sensor diagnostics.
This patented Moore Industries feature saves costly lost production time and hours of troubleshooting.
If the sensor breaks or otherwise stops sending a signal during operation, the transmitter instantly displays the type and location of the error on its display.
The TFZ has 20-bit input resolution, RFI/EMI protection, ambient temperature compensation, works up to five years between scheduled calibrations, and - depending on the sensor chosen - has an input accuracy up to +/-0.1 deg C.
An advanced linearization method minimizes conformance error, while Reference (Cold) Junction Compensation techniques produce stable readings even in fluctuating ambient temperature conditions.
For non-linear inputs, custom linearization curves can be programmed using the fieldbus configuration tool.
The TFZ can be trimmed with two data points within the selected zero and span measurement range.
This allows a complete process range to be monitored, while placing measurement emphasis on a specific segment of the range most critical to the process.
* Function block programming - the TFZ can be remotely programmed or interrogated over the segment using a standard FOUNDATION fieldbus configuration tool.
Function blocks include the following.
* Resource Function Block (RB) - contains diagnostic information, hardware and electronics information (memory, manufacturer identification, device type, software tag) and display configuration parameters.
* Temperature Transducer Block (TB) - contains temperature measurement data, including sensor and terminal temperature.
It also includes information about the sensor type, engineering units, linearization, re-ranging, damping, temperature compensation and diagnostics.
* Analog Input Block (AI) - processes measurements from a sensor and makes them available to other function blocks.
The output value from the AI block is displayed in engineering units and contains a status indicating the quality of the measurement.
• Moore Industries International: contact details and other news
• Email this article to a colleague
• Register for the free Manufacturingtalk email newsletter
• Manufacturingtalk Home Page