Product category:
Factory data acquisition
News Release from: Strategic Test | Subject: Digitizers
Edited by the Manufacturingtalk Editorial
Team on 11 May 2007
Dual time base mode for PCI waveform
digitizers
Strategic Test has introduced a dual time base option for its range of UltraFast Oscilloscope/Digitizer PCI cards which allows sample rates to be changed from slow to fast following a trigger event.
Strategic Test has introduced a dual time base option for its line of UltraFast Oscilloscope/Digitizer PCI cards Called the ABA Mode, this allows the cards to be configured for slow continuous recording, similar to a data logger, switch to high-speed sampling on detection of the trigger event, and then return to slow recording until the next trigger event
This article was originally published on Manufacturingtalk on 1 Jun 2007 at 8.00am (UK)
Related stories
PCI express waveform digitizer could be a first
Strategic Test has announced what they claim is the world's first PCI express waveform digitizer with 8-channel 3 MS/s 16-bit A/D boards and up to 4 GigaBytes memory.
Oscilloscope and AWG to control external equipment
Strategic Test has announced the BaseXIO option which allows their oscilloscope and AWG cards to control external equipment, and option adds 8 asynchronous TTL channels.
A timestamp is recorded for each trigger event.
A pre-trigger can be set so that data is recorded prior to the trigger event at the fast sample rate.
The main uses for the ABA mode are applications that need a recorded history of a process, both leading up to and after the trigger event.
For example, safety critical applications and quality testing can require continuous monitoring and high-speed recording in the event of a process or production failure.
While it is possible to pre-define the total number of samples to record so that the measurement card stops by itself, the most common use is likely to be where the measured data is continuously recorded to hard disk for audit trails.
The maximum speed that data can be recorded to hard disk is 200 MBytes/s when using a RAID controller coupled to four S-ATA disks.
The slowest and fastest sampling rates that can be selected for the ABA mode are a function of the Digitizer/Oscilloscope card used.
Strategic Test offers more than 80 different PCI cards.
The minimum sampling rate is 1 kSamples per second on all cards, while maximum sample rates for different cards are : 16-bit resolution : 3, 1, 0.5, 0.25 MSamples/s, 14-bit resolution : 50 or 20 MSamples/s, 12-bit resolution: 200, 160, 100, 80, 50, 25, 10, 1 MSamples/s, 8-bit resolution : 200, 100, 50 MSamples per second.
Cards are available with between 1 and 16 channels.
The ABA mode is included in an option bundle together with the Multiple Recording (memory segmentation), Gated Sampling (start/stop sample clock by external TTL signal) and the Timestamp option.
• Strategic Test: contact details and other news
• Email this article to a colleague
• Register for the free Manufacturingtalk email newsletter
• Manufacturingtalk Home Page

