News Release from: Tyco Flow Controls | Subject: PV vessel sampling device
Edited by the Manufacturingtalk Editorial
Team on 27 October 2003
Reactor sampler avoids shutdown
The problem of obtaining process samples from reactor vessels without requiring process shutdown has been solved by the PV vessel sampling device from Neotecha.
The problem of obtaining process samples from reactor vessels without requiring process shutdown has been solved by the PV vessel sampling device from Neotecha The sampling device is designed specifically to lift samples from reactor vessels under process conditions, producing more accurate results
This article was originally published on Manufacturingtalk on 6 Sep 2001 at 8.00am (UK)
Related stories
Actuator offers economical valve operation
Tyco Valves and Controls have launched their new PremiAir pneumatic actuator, designed to provide reliable, compact and economical valve operation.
Butterfly valves designed for hygenic applications
Hygienic butterfly valves designed for sanitary and aseptic applications in food, dairy, brewing, pharmaceutical and chemical industries come with standard butt weld and threaded end connections.
The PV is capable of extracting even highly corrosive or toxic media, while its design eliminates the possibility of any hazardous liquid or gaseous release to atmosphere.
The PV's vacuum operation lifts liquid from the reactor through a heavy duty PFA suction hose, which is located within the dip tube inside the vessel.
The media flows upward into the sight glass through a ball valve, which can be supplied in a dead-spot free 'C-ball' design that prevents retention of residual media after sampling is completed.
A PTFE hollow ball inside the sight glass rests on the top of the rising sampled liquid, and interrupts the vacuum when the sight glass is full, preventing over-extraction or liquid entering the vacuum line.
Once in the sight glass, the sample passes at atmospheric pressure through a transfer device to the sample bottle for testing.
The PV is suitable for either manual or automatic operation.
Neotecha also offers the option of a failsafe bottle-sensing device.
The device senses if the bottle has been correctly attached before undertaking sample transfer, eliminating the possibility of accidental spillage.
For periodic pH measurement, a probe adapter can be fitted.
Liquid can be simply drawn from the vessel into the sight glass, tested, and replaced into the reactor without needing to expose the pH probe to potentially corrosive substances for long periods.
The PV is available either in stainless steel or lined, with wetted parts in pfa, PTFE, or glass.
It is pressure rated to 10bar, and temperature rated to +200§C.
PV is available with a sample volume of either 150, 250, 500 or 1000ml.
Neotecha products are available from Tyco Valves and Controls.